Ultra Light System

Dry Envelopes

ULTRA LIGHT IS USED FOR BUILDINGS WITH IRREGULAR WINDOWS AND OPENINGS AND A LARGE QUANTITY OF PROTRUSIONS AND BALCONIES:

Ultra Light is a system based on the following generic layers of outer covering:
- Building wall in reinforced concrete or brick;
- Insulation with water-repellent layer;
- Adjustable anchoring brackets fixed to the wall with plugs or Halfen connectors;
- Vertical uprights;
- Horizontal beams;
- Vertical load transfer profiles anchored to the cross beams;
- Structural joint;
- Safety mesh (optional);
- Ultra slab;
- Mechanical retainer if required (recommended).

Ultra Light System

ULTRA LIGHT SYSTEM LAYING SEQUENCE

HAVING ESTABLISHED THE EXECUTIVE DESIGN OF THE FAÇADE, THE ULTRA LIGHT SYSTEM, COMPARED TO THE ULTRA FRAME, REQUIRES THE LAYING OF A GRID ON THE FAÇADE, AND WORK CAN BEGIN ON SITE TO MOUNT THIS WHILE THE ELEMENTS ARE BEING PREPARED AT THE FACTORY.
In most cases, the size of the Ultra Light panels allows the use of conventional scaffolding.

A typical installation sequence can be described as follows:
- Fitting of mechanical anchorages on the wall to be covered (generally brackets and plugs)
- Raising the materials
- Sealing and tightening the brackets
- Laying the insulating layer, if required
- Laying the vertical uprights
- Laying the horizontal beams
- Mechanically anchoring the panels to the beams
- Finely adjusting each cell in the two main directions
- Closing the ventilation gaps with grilles
- Fitting the terminal elements and window intrados

Ultra Light System

ULTRA LIGHT SITE LOGISTICS

In most cases, the size of the Ultra Light panels allows the use of conventional scaffolding, and site logistics are therefore very similar to those
for assembling traditional ceramic ventilated façades; as an example the following families are indicated:

Access for staff working at a height: Handling and laying:
- Fixed scaffolding - Site crane
- Mobile scaffolding - Mobile crane

ULTRA LIGHT COVERING SYSTEM SIZE RANGE AND USE

Ultra Light System

NOTE: The size range is purely indicative, as external coverings can be produced using slabs of all sizes (up to 180x150 cm).

The key refers to the height above ground of the building.

XPS: Extruded polystyrene
EPS: Sintered expanded polystyrene

Information request

Fill in the form below to contact Ariostea and request information of any kind; we will contact you as soon as we can.
Enter a correct, active email address.
Fields marked * are compulsory.




Add your Wishlist to your enquiry!
0
Do not include in e-mail
call me Please call me as soon as possible.

I want to receive Ariostea's newsletter.
I want to receive Ariostea's newsletter.


PRIVACY
* I hereby confirm that i have read understood and accepted the terms of the information on the processing of personal data (privacy policy).


Click on the padlock symbol below to enable the Send button